ComCap 4.2 beta
ComCap is a Windows program developed to capture any ASCII data received on PC serial communications ports to text files.
ComCap is a Windows program developed to capture any ASCII data received on PC serial communications ports to text files.
Here are some key features of "ComCap":
The ComCap system tray icon now shows a small red or green square to indicate whether capture is stopped or started.
If ComCap is unregistered, an alert is now sent when capture starts and when it stops after one hour (24 hours with a v3 license). This will serve as a warning if the license key is lost or corrupted.
Both the Information Log and Alerts may now be sent to a remote PC using UDP, TCP Client or TCP Server protocols, perhaps to another copy of ComCap. This will ease central monitoring of remote capture.
The Alert window will now appear without also showing the tray capture window, which avoids unnecessary log scrolling on unattended PCs.
Echo to Remote using UDP now pings the remote host before sending any data to establish it exists, and continues to ping at the 'Wait Seconds' interval during the capture session to ensure it's still available. Note this does not mean a UDP server is listening on the remote computer, just that the computer is running. This is disabled if Common Preferences 'Don't Check Connections with Ping Echo' is ticked.
When using Echo to Remote with Syslog, the Severity and Facility Priorities are now selected from drop down lists, rather than needing to enter a numeric value (ie ).
The ComCap application and set-up program are now both digitally signed as being from Magenta Systems Ltd. This will reduce the severity of the warnings that Windows Vista generates when programs are run.
Fixed a bug with capture using TCP Server where an optional Start Command was only sent for the server remote connection, and not subsequent connections.
Fixed a bug that meant the service version did not always log version and registration information on start-up.
Fixed a bug that meant an unnecessary 'emergency' information log file might have been created in the program directory on start-up or close down. Such logs are generally only created when the correct log volume is not available or the log file can not be opened due to an error.
In Common Settings, Serial Ports, a new tick box 'Check Serial CTS/DSR Lines' has been added. If ticked, capture will only start when both the CTS and DSR control lines are high, and will stop if they drop. This should make detection of connection or hardware problems much easier since an alert can be sent if capture stops.
In Common Settings, Log Files, a new tick box 'Send Alert on File Errors' has been added. If ticked, any major errors opening or writing the information or capture logs will generate an alert. Currently there may be repeated alerts, since such errors often happen rapidly on multiple channels, but this should be fixed shortly.
In Common Settings, Capture Logging, a new tick box 'Send Alert on Stop' has been added. If ticked, an alert is sent every time ComCap is stopped. This is intended for where ComCap should be running 24/7, and where alerts are sent via email, SMS or remotely to warn of accidental stops. Note this will only work for a 'clean' close down, if ComCap is crashed from Task Manager or by Windows close down, the alert may not be sent.
Attempted to handle a situation with the service version where a serious problem that causes hundreds or thousands of error lines in the information log could potentially overflow the 'echo to tray' communication channel and lock-up ComCap.
Made a few improvements in ComGen. It will now close down faster when Windows itself closes down. UDP Client now pings the remote host before sending any data to establish it exists, and continues to ping during the ession to ensure it's still available. Corrected the default Data Types that still had s8 for a serial number (from an earlier beta) instead of #8 used in the final release.
tags
close down this will has been the remote common settings been added new tick tick box information log the information the service that meant are now
Download ComCap 4.2 beta
Download ComCap 4.2 beta
Purchase:
Buy ComCap 4.2 beta
Similar software
ComCap 4.2 beta
Magenta Systems Ltd
ComCap is a Windows program developed to capture any ASCII data received on PC serial communications ports to text files.
Virtual Serial Port Control 3.5
FabulaTech, Inc.
Virtual Serial Port Control is an ActiveX control which makes it possible to create virtual serial ports and fully control them.
Serial-File 1.51
Fog Software, Inc.
Serial-File is a program intended for logging data received from serial port(s) to a text file.
JComm Serial Communications Application 1.01
Scott Harrison
JComm is created to capture data from the serial port of your PC, tokenize the data and then export the data into a text file with user defined delimiters.
Windows Standard Serial Communications Library for Delphi 4.2
MarshallSoft Computing
The Windows Standard Serial Communications Library for Delphi (WSC4D) gives you an serial communication library based on the Windows API.
Network Serial Port Kit 6.1
FabulaTech Inc
Network Serial Port Kit will allow you to connect any serial port devices over the TCP/IP network or Internet.
Serial Receptor 1.4
JMM
Serial Receptor is a easy tool to capture all data on your serial ports.
Serial Device Test Utility 1.5.0.13
H.A.c.K. Consulting
The Serial device test utility is designed to assist with the debugging of serial communications.
RS232 Stealth Monitor 1.0
Virtual Integrated Design
RS232 Stealth Monitor is a useful utility that shows serial data transmitted and received from an rs232 com port on the same pc with no extra hardware!
View and log RS232 data in Hex or Ascii mode.
Share Serial Ports 1.0
ELTIMA Software GmbH
Share Serial Ports is an advanced utility, the purpose of which is to share real serial ports between multiple applications in the way, that all applications will receive same data from real serial port simultaneously.